  "capturedAt": "2026-11-07T09:52:25.508Z",
  "route": "/solutions/canopen-servo-drive-for-inspection-robot",
  "method": "Playwright Chromium production browser screenshot; default inputs compared with the deterministic engine.",
  "boundary": "Reproducible software execution only; not hardware testing, customer evidence, product qualification, safety or hazardous-area approval.",
  "screenshot": {
    "path": "/evidence/canopen-inspection-evaluator.webp",
    "width": 1080,
    "height": 1200,
    "bytes": 148338,
    "sha256": "1d41c39d63b068e8b5a76bc10f83ee4b2a8fb37c3127b5e6e78185032b23a2a1"
  },
  "inputs": {
    "numAxes": "4",
    "driveRole": "traction",
    "loadTorqueNm": "28",
    "peakTorqueNm": "75",
    "gearRatio": "25",
    "gearEfficiency": "85",
    "crawlSpeedRpm": "1.0",
    "maxSpeedRpm": "80",
    "torqueConstant": "0.08",
    "motorResistanceOhm": "0.12",
    "encoderResolutionBits": "17",
    "supplyVoltage": "48",
    "tetherLengthM": "2",
    "tetherWireAwg": "16",
    "baudRateKbps": "500",
    "syncCycleMs": "2.0",
    "enclosureType": "ip67_sealed_chassis",
    "ambientTempC": "45",
    "holdingBrakeEquipped": "yes"
  },
  "result": {
    "motorTorqueContNm": 1.3176470588235294,
    "motorTorquePeakNm": 3.5294117647058822,
    "motorSpeedMaxRpm": 2000,
    "motorSpeedCrawlRpm": 25,
    "currentRmsContA": 16.470588235294116,
    "currentRmsPeakA": 44.11764705882353,
    "tetherResistanceOhm": 0.05268,
    "tetherVoltageDropPeakV": 5.726900451646031,
    "voltageAtDrivePeakV": 42.27309954835397,
    "backEmfPeakV": 13.68053152172655,
    "voltageHeadroomV": 21.0473364341376,
    "voltageRiskLevel": "safe",
    "tetherPowerFeasible": true,
    "driveLossesContW": 12.661314878892732,
    "driveLossesPeakW": 59.83044982698962,
    "enclosureTempRiseC": 91.16146712802767,
    "estimatedJunctionTempC": 146.29051903114183,
    "thermalRiskLevel": "critical",
    "velocityQuantizationRpm": 0.018310546875,
    "jitterRatioPercent": 1.8310546875,
    "canWireTimeUs": 2270,
    "canBusLoadPercent": 113.5,
    "maxRecommendedTetherM": 100,
    "tetherBaudConflict": false,
    "busLoadStatus": "overloaded",
    "brakeSafetyStatus": "not_assessed",
    "actionableInsights": [
      "Estimated MOSFET junction temperature (146.3 deg C) exceeds the illustrative screening ceiling for ip67_sealed_chassis enclosures (115 deg C). Increase chassis heat-sink conduction surface or reduce continuous current. Verify device ratings and measured enclosure/surface temperatures; this is not a T4 assessment.",
      "CANopen cyclic wire load (113.5%) exceeds the 70% threshold. Increase the SYNC period to at least 4.54 ms for a 50% cyclic budget or partition traction and gimbal axes onto separate physical CAN buses.",
      "Planning estimates only: verify motor/drive data, measured thermal resistance, actual motion duty, brake capacity and system safety before procurement."
    ]
  },
  "resultText": "Evaluated Sizing Metrics & Bus Feasibility\n\nIllustrative screening estimates, not product ratings or certification. Edit inputs below to update results immediately.\n\nCopy to RFQ\nView RFQ Text\n\nResults updated. Review assumptions and findings before copying your RFQ.\n\nEdit sizing inputs\nAssumptions: identical axes at simultaneous peak torque and maximum speed; copper at 20 deg C; a constant-power tether load; illustrative inverter losses and whole-pod thermal resistance. Terminal voltage is unavailable when that load has no sustainable operating point. Count step is not measured jitter. Brake capacity, STO/SBC, ingress ratings and hazardous-area compliance require separate validation.Method, sources and limits\n\nMotor Shaft Torque & Current\n\n1.32 Nm cont\n16.47 Arms\n\nPeak: 3.53 Nm @ 44.12 Arms | Max Speed: 2,000 RPM\n\nTether Drop & Terminal Voltage\n\n42.3 V at drive\nDrop: -5.7V\n\nHeadroom: 21V | Tether R: 0.05 ohm (2m)\n\nSealed Thermal Rise & Junction\n\n146.3 deg C T_j\nRise: +91.2C\n\nLosses: 12.7W cont / 59.8W pk (ip67_sealed_chassis)\n\nIdeal Encoder Count Step (1 ms sampling)\n\n0.0183 RPM step\n1.8% of creep speed\n\nResolution: 17-bit (131,072 CPR)\n\nCANopen Wire Transmission Load\n\n113.5% bus load\n2,270 us\n\n4 axes (8 PDOs + SYNC) @ 2.0 ms cycle\n\nTether Propagation Feasibility\n\nWithin length guide\nMax: 100 m\n\nTether: 2 m @ 500 kbps (CiA length guide; topology not evaluated)\n\nACTIONABLE ENGINEERING AUDIT FINDINGS\n\nEstimated MOSFET junction temperature (146.3 deg C) exceeds the illustrative screening ceiling for ip67_sealed_chassis enclosures (115 deg C). Increase chassis heat-sink conduction surface or reduce continuous current. Verify device ratings and measured enclosure/surface temperatures; this is not a T4 assessment.\nCANopen cyclic wire load (113.5%) exceeds the 70% threshold. Increase the SYNC period to at least 4.54 ms for a 50% cyclic budget or partition traction and gimbal axes onto separate physical CAN buses.\nPlanning estimates only: verify motor/drive data, measured thermal resistance, actual motion duty, brake capacity and system safety before procurement.\nCopy Sizing Specification\nRequest Factory RFQ",
  "rfqText": "### CANopen Servo Drive Sizing Specification (Inspection Robot)\n- Robot Subsystem Role: traction\n- Number of Active Axes: 4\n- Actuator Load: 28 Nm cont / 75 Nm peak\n- Gearhead: 25:1 ratio @ 85% efficiency\n- Motion Speeds: Creep 1.0 RPM, Max 80 RPM\n- Motor Specs: Kt = 0.08 Nm/Arms, R = 0.12 ohm\n- Feedback Resolution: 17-bit encoder\n- DC Power: 48 VDC supply, Tether: 2 m (16 AWG)\n- CANopen Bus: 500 kbps, SYNC period = 2.0 ms\n- Enclosure / Ambient: ip67_sealed_chassis @ 45 deg C\n- Holding Brake: yes\n\n### Illustrative Screening Results (not a validated drive selection)\n- Motor Shaft Torque: 1.32 Nm cont / 3.53 Nm peak\n- Phase Current: 16.47 Arms cont / 44.12 Arms peak\n- Tether DC Sag: 5.73 V drop -> Terminal 42.27 V (Headroom: 21.05 V)\n- Sealed Heat Dissipation: 12.66 W cont -> Junction Temp: 146.29 deg C\n- Ideal 1ms Count Step: 0.0183 RPM quantization (1.8% of creep speed)\n- CANopen Wire Load: 2,270 us wire time (113.5% of SYNC period)\n- Max Rec Tether at 500 kbps: 100 m\n\n### Assumptions and Required Follow-Up\nAll axes assumed identical and simultaneously at peak torque AND maximum speed; actual duty may differ.\nCopper resistance at 20 deg C; constant-power tether model; illustrative inverter and enclosure thermal values.\nCount step is not measured jitter. Brake capacity, STO/SBC, ingress and hazardous-area compliance are not assessed.\n- Estimated MOSFET junction temperature (146.3 deg C) exceeds the illustrative screening ceiling for ip67_sealed_chassis enclosures (115 deg C). Increase chassis heat-sink conduction surface or reduce continuous current. Verify device ratings and measured enclosure/surface temperatures; this is not a T4 assessment.\n- CANopen cyclic wire load (113.5%) exceeds the 70% threshold. Increase the SYNC period to at least 4.54 ms for a 50% cyclic budget or partition traction and gimbal axes onto separate physical CAN buses.\n- Planning estimates only: verify motor/drive data, measured thermal resistance, actual motion duty, brake capacity and system safety before procurement."
}